AnalogX

AnalogX CAN bus API

Overview

The CAN bus API provides the configuration and control interface for AnalogX

CAN Messages

CAN base ID

CAN base ID is 0xE4600 (935424)

Adjusting Base ID

The base address is determined by the state of the ADR1 and ADR2 jumpers. By default, the jumpers are bridged; cutting the jumper ADR1 will add 256 to the base ID, and cutting jumper ADR2 will add 512 to the base ID.

The combination of jumper settings will allow up to 4 AnalogX units to coexist on the same CAN bus.

ADR2 ADR1 Address
Default Default 0xE4600 (935424)
Default Cut 0xE4700 (935680)
Cut Default 0xE4800 (935936)
Cut Cut 0xE4900 (936192)

CAN Baud rate

500K and 1MB rates are supported.

500K is enabled by default; cut the jumper labeled BAUD on the bottom of AnalogX to enable 1MB rate.

Announcement

Broadcast by the device upon power up

Address

CAN ID: Base + 0

Offset What Value
0 Channel Count Total number of channels on device
1 Reserved
2 Reserved
3 Reserved
4 Reserved
5 Major Version Firmware Major Version Number
6 Minor Version Firmware Minor Version Number
7 Patch Version Firmware Patch version number

Configuration Group 1

Configures options for AnalogX.

Send this message to AnalogX to configure runtime settings. These settings are volatile.

Address

CAN ID: Base + 3

Offset What Value
0 Sample Rate Rate to report sensor values ( 1 - 255Hz). Default sample rate is 50Hz.
1 Reserved
2 Reserved
3 Reserved
4 Reserved
5 Reserved
6 Reserved
7 Reserved

Sample Broadcast

Sample Broadcast for Analog inputs. The samples are broadcast based on the configured sample rate (default is 50Hz)

Scaling and Data format

  • Scaling: 0-5000mV
  • Data format: Little Endian

Address

  • CAN ID: Base + 20
Offset What Value
0 Channel 1, low byte
1 Channel 1, high byte
2 Channel 2, low byte
3 Channel 2, high byte
4 Channel 3, low byte
5 Channel 3, high byte
6 Channel 4, low byte
7 Channel 4, high byte