Emtron

Revision as of 03:15, 5 February 2015 by Brentp (talk | contribs) (→‎Emtron ECU)

Emtron ECU

Emtron KV8.jpg

Configuration

This script integrates the Emtron ECU with RaceCapture/Pro telemetry.

Baud Rate

Baud Rate is:

Channels

TPS

  • CAN ID: 1251
  • Bytes: 5,6
  • Scaling: 0 = -100.0% ; 2000 = 100.0%


Lua Script


setTickRate(30) --30Hz

--set up virtual channels
tps_id = addChannel("TPS", 10, 1)

--handle TPS message data
function process_tps(data)
    local tps = data[5] * 256 + data[6]
    tps = (tps - 1000) / 10
    setChannel(tps_id, tps)
end

function onTick()
    repeat --will drain CAN buffer on each tick
        id, e, data = rxCAN(0)
        if id == 1251 then process_tps(data) end
    until id == nil
end